Part Number Hot Search : 
STP60N 84C10 MVTX1100 BT2222 30BQ04 LD1117E 02J1AVS2 4148SE
Product Description
Full Text Search
 

To Download ID8259A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 8259A PROGRAMMABLE INTERRUPT CONTROLLER (8259A 8259A-2)
Y Y Y Y Y Y
8086 8088 Compatible MCS-80 MCS-85 Compatible Eight-Level Priority Controller Expandable to 64 Levels Programmable Interrupt Modes Individual Request Mask Capability
Y Y
Single a 5V Supply (No Clocks) Available in 28-Pin DIP and 28-Lead PLCC Package
(See Packaging Spec Order 231369)
Y
Available in EXPRESS Standard Temperature Range Extended Temperature Range
The Intel 8259A Programmable Interrupt Controller handles up to eight vectored priority interrupts for the CPU It is cascadable for up to 64 vectored priority interrupts without additional circuitry It is packaged in a 28-pin DIP uses NMOS technology and requires a single a 5V supply Circuitry is static requiring no clock input The 8259A is designed to minimize the software and real time overhead in handling multi-level priority interrupts It has several modes permitting optimization for a variety of system requirements The 8259A is fully upward compatible with the Intel 8259 Software originally written for the 8259 will operate the 8259A in all 8259 equivalent modes (MCS-80 85 Non-Buffered Edge Triggered) DIP
231468 - 2
PLCC
231468 - 31 231468 - 1
Figure 1 Block Diagram
Figure 2 Pin Configurations
December 1988
Order Number 231468-003
8259A
Table 1 Pin Description Symbol VCC GND CS Pin No 28 14 1 Type I I I SUPPLY a 5V Supply GROUND CHIP SELECT A low on this pin enables RD and WR communication between the CPU and the 8259A INTA functions are independent of CS WRITE A low on this pin when CS is low enables the 8259A to accept command words from the CPU READ A low on this pin when CS is low enables the 8259A to release status onto the data bus for the CPU BIDIRECTIONAL DATA BUS Control status and interrupt-vector information is transferred via this bus CASCADE LINES The CAS lines form a private 8259A bus to control a multiple 8259A structure These pins are outputs for a master 8259A and inputs for a slave 8259A SLAVE PROGRAM ENABLE BUFFER This is a dual function pin When in the Buffered Mode it can be used as an output to control buffer transceivers (EN) When not in the buffered mode it is used as an input to designate a master (SP e 1) or slave (SP e 0) INTERRUPT This pin goes high whenever a valid interrupt request is asserted It is used to interrupt the CPU thus it is connected to the CPU's interrupt pin INTERRUPT REQUESTS Asynchronous inputs An interrupt request is executed by raising an IR input (low to high) and holding it high until it is acknowledged (Edge Triggered Mode) or just by a high level on an IR input (Level Triggered Mode) INTERRUPT ACKNOWLEDGE This pin is used to enable 8259A interrupt-vector data onto the data bus by a sequence of interrupt acknowledge pulses issued by the CPU AO ADDRESS LINE This pin acts in conjunction with the CS WR and RD pins It is used by the 8259A to decipher various Command Words the CPU writes and status the CPU wishes to read It is typically connected to the CPU A0 address line (A1 for 8086 8088) Name and Function
WR RD D7 -D0 CAS0 -CAS2
2 3 4-11 12 13 15
I I IO IO
SP EN
16
IO
INT
17
O
IR0 -IR7
18-25
I
INTA
26
I
A0
27
I
2
8259A
FUNCTIONAL DESCRIPTION Interrupts in Microcomputer Systems
Microcomputer system design requires that I O devices such as keyboards displays sensors and other components receive servicing in a an efficient manner so that large amounts of the total system tasks can be assumed by the microcomputer with little or no effect on throughput The most common method of servicing such devices is the Polled approach This is where the processor must test each device in sequence and in effect ``ask'' each one if it needs servicing It is easy to see that a large portion of the main program is looping through this continuous polling cycle and that such a method would have a serious detrimental effect on system throughput thus limiting the tasks that could be assumed by the microcomputer and reducing the cost effectiveness of using such devices A more desirable method would be one that would allow the microprocessor to be executing its main program and only stop to service peripheral devices when it is told to do so by the device itself In effect the method would provide an external asynchronous input that would inform the processor that it should complete whatever instruction that is currently being executed and fetch a new routine that will service the requesting device Once this servicing is complete however the processor would resume exactly where it left off This method is called Interrupt It is easy to see that system throughput would drastically increase and thus more tasks could be assumed by the microcomputer to further enhance its cost effectiveness The Programmable Interrupt Controller (PIC) functions as an overall manager in an Interrupt-Driven system environment It accepts requests from the peripheral equipment determines which of the incoming requests is of the highest importance (priority) ascertains whether the incoming request has a higher priority value than the level currently being serviced and issues an interrupt to the CPU based on this determination Each peripheral device or structure usually has a special program or ``routine'' that is associated with its specific functional or operational requirements this is referred to as a ``service routine'' The PIC after issuing an Interrupt to the CPU must somehow input information into the CPU that can ``point'' the Program Counter to the service routine associated with the requesting device This ``pointer'' is an address in a vectoring table and will often be referred to in this document as vectoring data Figure 3a Polled Method
231468 - 3
231468 - 4
Figure 3b Interrupt Method
3
8259A
The 8259A is a device specifically designed for use in real time interrupt driven microcomputer systems It manages eight levels or requests and has built-in features for expandability to other 8259A's (up to 64 levels) It is programmed by the system's software as an I O peripheral A selection of priority modes is available to the programmer so that the manner in which the requests are processed by the 8259A can be configured to match his system requirements The priority modes can be changed or reconfigured dynamically at any time during the main program This means that the complete interrupt structure can be defined as required based on the total system environment INTERRUPT REQUEST REGISTER (IRR) AND IN-SERVICE REGISTER (ISR) The interrupts at the IR input lines are handled by two registers in cascade the Interrupt Request Register (IRR) and the In-Service (ISR) The IRR is used to store all the interrupt levels which are requesting service and the ISR is used to store all the interrupt levels which are being serviced PRIORITY RESOLVER This logic block determines the priorites of the bits set in the IRR The highest priority is selected and strobed into the corresponding bit of the ISR during INTA pulse INTERRUPT MASK REGISTER (IMR) The IMR stores the bits which mask the interrupt lines to be masked The IMR operates on the IRR Masking of a higher priority input will not affect the interrupt request lines of lower quality INT (INTERRUPT) This output goes directly to the CPU interrupt input The VOH level on this line is designed to be fully compatible with the 8080A 8085A and 8086 input levels
INTA (INTERRUPT ACKNOWLEDGE) INTA pulses will cause the 8259A to release vectoring information onto the data bus The format of this data depends on the system mode (mPM) of the 8259A DATA BUS BUFFER This 3-state bidirectional 8-bit buffer is used to interface the 8259A to the system Data Bus Control words and status information are transferred through the Data Bus Buffer READ WRITE CONTROL LOGIC The function of this block is to accept OUTput commands from the CPU It contains the Initialization Command Word (ICW) registers and Operation Command Word (OCW) registers which store the various control formats for device operation This function block also allows the status of the 8259A to be transferred onto the Data Bus CS (CHIP SELECT) A LOW on this input enables the 8259A No reading or writing of the chip will occur unless the device is selected WR (WRITE) A LOW on this input enables the CPU to write control words (ICWs and OCWs) to the 8259A RD (READ) A LOW on this input enables the 8259A to send the status of the Interrupt Request Register (IRR) In Service Register (ISR) the Interrupt Mask Register (IMR) or the Interrupt level onto the Data Bus A0 This input signal is used in conjunction with WR and RD signals to write commands into the various command registers as well as reading the various status registers of the chip This line can be tied directly to one of the address lines
4
8259A
231468 - 5
Figure 4a 8259A Block Diagram
5
8259A
231468 - 6
Figure 4b 8259A Block Diagram
6
8259A
leased at the first INTA pulse and the higher 8-bit address is released at the second INTA pulse 7 This completes the 3-byte CALL instruction released by the 8259A In the AEOI mode the ISR bit is reset at the end of the third INTA pulse Otherwise the ISR bit remains set until an appropriate EOI command is issued at the end of the interrupt sequence The events occuring in an 8086 system are the same until step 4 4 Upon receiving an INTA from the CPU group the highest priority ISR bit is set and the corresponding IRR bit is reset The 8259A does not drive the Data Bus during this cycle 5 The 8086 will initiate a second INTA pulse During this pulse the 8259A releases an 8-bit pointer onto the Data Bus where it is read by the CPU 6 This completes the interrupt cycle In the AEOI mode the ISR bit is reset at the end of the second INTA pulse Otherwise the ISR bit remains set until an appropriate EOI command is issued at the end of the interrupt subroutine If no interrupt request is present at step 4 of either sequence (i e the request was too short in duration) the 8259A will issue an interrupt level 7 Both the vectoring bytes and the CAS lines will look like an interrupt level 7 was requested When the 8259A PIC receives an interrupt INT becomes active and an interrupt acknowledge cycle is started If a higher priority interrupt occurs between the two INTA pulses the INT line goes inactive immediately after the second INTA pulse After an unspecified amount of time the INT line is activated again to signify the higher priority interrupt waiting for service This inactive time is not specified and can vary between parts The designer should be aware of this consideration when designing a system which uses the 8259A It is recommended that proper asynchronous design techniques be followed
THE CASCADE BUFFER COMPARATOR This function block stores and compares the IDs of all 8259A's used in the system The associated three I O pins (CAS0-2) are outputs when the 8259A is used as a master and are inputs when the 8259A is used as a slave As a master the 8259A sends the ID of the interrupting slave device onto the CAS0-2 lines The slave thus selected will send its preprogrammed subroutine address onto the Data Bus during the next one or two consecutive INTA pulses (See section ``Cascading the 8259A'' ) INTERRUPT SEQUENCE The powerful features of the 8259A in a microcomputer system are its programmability and the interrupt routine addressing capability The latter allows direct or indirect jumping to the specific interrupt routine requested without any polling of the interrupting devices The normal sequence of events during an interrupt depends on the type of CPU being used The events occur as follows in an MCS-80 85 system 1 One or more of the INTERRUPT REQUEST lines (IR7-0) are raised high setting the corresponding IRR bit(s) 2 The 8259A evaluates these requests and sends an INT to the CPU if appropriate 3 The CPU acknowledges the INT and responds with an INTA pulse 4 Upon receiving an INTA from the CPU group the highest priority ISR bit is set and the corresponding IRR bit is reset The 8259A will also release a CALL instruction code (11001101) onto the 8-bit Data Bus through its D7-0 pins 5 This CALL instruction will initiate two more INTA pulses to be sent to the 8259A from the CPU group 6 These two INTA pulses allow the 8259A to release its preprogrammed subroutine address onto the Data Bus The lower 8-bit address is re-
7
8259A
231468 - 7
Figure 4c 8259A Block Diagram
INTERRUPT SEQUENCE OUTPUTS MCS-80 MCS-85
This sequence is timed by three INTA pulses During the first INTA pulse the CALL opcode is enabled onto the data bus Content of First Interrupt Vector Byte D7 D6 D5 D4 D3 D2 D1 D0 CALL CODE 1 1 0 0 1 1 0 1
231468 - 8
Figure 5 8259A Interface to Standard System Bus 8
During the second INTA pulse the lower address of the appropriate service routine is enabled onto the data bus When Interval e 4 bits A5 -A7 are programmed while A0 -A4 are automatically inserted by the 8259A When Interval e 8 only A6 and A7 are programmed while A0 -A5 are automatically inserted
8259A
composed as follows (note the state of the ADI mode control is ignored and A5 -A11 are unused in 8086 mode) Content of Interrupt Vector Byte for 8086 System Mode D7 IR7 IR6 IR5 IR4 IR3 IR2 IR1 IR D7 7 6 5 4 3 2 1 0 A7 A7 A7 A7 A7 A7 A7 A7 D6 A6 A6 A6 A6 A6 A6 A6 A6 D5 1 1 1 1 0 0 0 0 Interval e 8 D4 1 1 0 0 1 1 0 0 D3 1 0 1 0 1 0 1 0 D2 0 0 0 0 0 0 0 0 D1 0 0 0 0 0 0 0 0 D0 0 0 0 0 0 0 0 0 IR0 T7 T7 T7 T7 T7 T7 T7 T7 D6 T6 T6 T6 T6 T6 T6 T6 T6 D5 T5 T5 T5 T5 T5 T5 T5 T5 D4 T4 T4 T4 T4 T4 T4 T4 T4 D3 T3 T3 T3 T3 T3 T3 T3 T3 D2 1 1 1 1 0 0 0 0 D1 1 1 0 0 1 1 0 0 D0 1 0 1 0 1 0 1 0
Content of Second Interrupt Vector Byte IR D7 7 6 5 4 3 2 1 0 A7 A7 A7 A7 A7 A7 A7 A7 D6 A6 A6 A6 A6 A6 A6 A6 A6 D5 A5 A5 A5 A5 A5 A5 A5 A5 Interval e 4 D4 1 1 1 1 0 0 0 0 D3 1 1 0 0 1 1 0 0 D2 1 0 1 0 1 0 1 0 D1 0 0 0 0 0 0 0 0 D0 0 0 0 0 0 0 0 0
PROGRAMMING THE 8259A
The 8259A accepts two types of command words generated by the CPU 1 Initialization Command Words (ICWs) Before normal operation can begin each 8259A in the system must be brought to a starting point by a sequence of 2 to 4 bytes timed by WR pulses 2 Operation Command Words (OCWs) These are the command words which command the 8259A to operate in various interrupt modes These modes are a Fully nested mode b Rotating priority mode c Special mask mode d Polled mode The OCWs can be written into the 8259A anytime after initialization
During the third INTA pulse the higher address of the appropriate service routine which was programmed as byte 2 of the initialization sequence (A8 -A15) is enabled onto the bus Content of Third Interrupt Vector Byte D7 D6 D5 D4 D3 D2 D1 D0 A15 A14 A13 A12 A11 A10 A9 A8
8086 8088
8086 mode is similar to MCS-80 mode except that only two Interrupt Acknowledge cycles are issued by the processor and no CALL opcode is sent to the processor The first interrupt acknowledge cycle is similar to that of MCS-80 85 systems in that the 8259A uses it to internally freeze the state of the interrupts for priority resolution and as a master it issues the interrupt code on the cascade lines at the end of the INTA pulse On this first cycle it does not issue any data to the processor and leaves its data bus buffers disabled On the second interrupt acknowledge cycle in 8086 mode the master (or slave if so programmed) will send a byte of data to the processor with the acknowledged interrupt code
INITIALIZATION COMMAND WORDS (ICWS) General
Whenever a command is issued with A0 e 0 and D4 e 1 this is interpreted as Initialization Command Word 1 (ICW1) ICW1 starts the intiitalization sequence during which the following automatically occur a The edge sense circuit is reset which means that following initialization an interrupt request (IR) input must make a low-to-high transistion to generate an interrupt
9
8259A
b The Interrupt Mask Register is cleared c IR7 input is assigned priority 7 d The slave mode address is set to 7 e Special Mask Mode is cleared and Status Read is set to IRR f If IC4 e 0 then all functions selected in ICW4 are set to zero (Non-Buffered mode no AutoEOI MCS-80 85 system) case SNGL e 0 It will load the 8-bit slave register The functions of this register are a In the master mode (either when SP e 1 or in buffered mode when M S e 1 in ICW4) a ``1'' is set for each slave in the system The master then will release byte 1 of the call sequence (for MCS80 85 system) and will enable the corresponding slave to release bytes 2 and 3 (for 8086 only byte 2) through the cascade lines b In the slave mode (either when SP e 0 or if BUF e 1 and M S e 0 in ICW4) bits 2 - 0 identify the slave The slave compares its cascade input with these bits and if they are equal bytes 2 and 3 of the call sequence (or just byte 2 for 8086) are released by it on the Data Bus
NOTE Master Slave in ICW4 is only used in the buffered mode
Initialization Command Words 1 and 2 (ICW1 ICW2)
A5 -A15 Page starting address of service routines In an MCS 80 85 system the 8 request levels will generate CALLs to 8 locations equally spaced in memory These can be programmed to be spaced at intervals of 4 or 8 memory locations thus the 8 routines will occupy a page of 32 or 64 bytes respectively The address format is 2 bytes long (A0 -A15) When the routine interval is 4 A0 -A4 are automatically inserted by the 8259A while A5 -A15 are programmed externally When the routine interval is 8 A0 -A5 are automatically inserted by the 8259A while A6 -A15 are programmed externally The 8-byte interval will maintain compatibility with current software while the 4-byte interval is best for a compact jump table In an 8086 system A15 -A11 are inserted in the five most significant bits of the vectoring byte and the 8259A sets the three least significant bits according to the interrupt level A10 -A5 are ignored and ADI (Address interval) has no effect LTIM If LTIM e 1 then the 8259A will operate in the level interrupt mode Edge detect logic on the interrupt inputs will be disabled ADI CALL address interval ADI e 1 then interval e 4 ADI e 0 then interval e 8 SNGL Single Means that this is the only 8259A in the system If SNGL e 1 no ICW3 will be issued IC4 If this bit is set ICW4 has to be read If ICW4 is not needed set IC4 e 0
231468 - 9
Initialization Command Word 3 (ICW3)
This word is read only when there is more than one 8259A in the system and cascading is used in which
Figure 6 Initialization Sequence
10
8259A
master M S e 0 means the 8259A is programmed to be a slave If BUF e 0 M S has no function If AEOI e 1 the automatic end of interrupt mode is programmed Microprocessor mode mPM e 0 sets the 8259A for MCS-80 85 system operation mPM e 1 sets the 8259A for 8086 system operation
Initialization Command Word 4 (ICW4)
SFNM If SFNM e 1 the special fully nested mode is programmed BUF If BUF e 1 the buffered mode is programmed In buffered mode SP EN becomes an enable output and the master slave determination is by M S MS If buffered mode is selected M S e 1 means the 8259A is programmed to be a AEOI mPM
231468 - 10
231468 - 11
Figure 7 Initialization Command Word Format
11
8259A
231468 - 12
231468 - 13
231468 - 14
NOTE Slave ID is equal to the corresponding master IR input
Figure 7 Initialization Command Word Format (Continued)
12
8259A
OPERATION COMMAND WORDS (OCWS)
After the Initialization Command Words (ICWs) are programmed into the 8259A the chip is ready to accept interrupt requests at its input lines However during the 8259A operation a selection of algorithms can command the 8259A to operate in various modes through the Operation Command Words (OCWs)
Operation Control Words (OCWs)
A0 1 D7 M7 D6 M6 OCW1 D5 D4 D3 D2 D1 D0 M5 M4 M3 M2 M1 M0
OCW2 0 R SL EOI OCW3 0 0 ESMM SMM 0 1 P RR RIS 0 0 L2 L1 L0
231468 - 15
231468 - 16
Figure 8 Operation Command Word Format
13
8259A
Operation Control Word 1 (OCW1)
OCW1 sets and clears the mask bits in the interrupt Mask Register (IMR) M7 -M0 represent the eight mask bits M e 1 indicates the channel is masked (inhibited) M e 0 indicates the channel is enabled
Operation Control Word 2 (OCW2)
R SL EOI These three bits control the Rotate and End of Interrupt modes and combinations of the two A chart of these combinations can be found on the Operation Command Word Format L2 L1 L0 These bits determine the interrupt level acted upon when the SL bit is active
231468 - 17
Figure 8 Operation Command Word Format (Continued)
14
8259A
When a mode is used which may disturb the fully nested structure the 8259A may no longer be able to determine the last level acknowledged In this case a Specific End of Interrupt must be issued which includes as part of the command the IS level to be reset A specific EOI can be issued with OCW2 (EOI e 1 SL e 1 R e 0 and L0 - L2 is the binary level of the IS bit to be reset) It should be noted that an IS bit that is masked by an IMR bit will not be cleared by a non-specific EOI if the 8259A is in the Special Mask Mode
Operation Control Word 3 (OCW3)
ESMM Enable Special Mask Mode When this bit is set to 1 it enables the SMM bit to set or reset the Special Mask Mode When ESMM e 0 the SMM bit becomes a ``don't care'' SMM Special Mask Mode If ESMM e 1 and SMM e 1 the 8259A will enter Special Mask Mode If ESMM e 1 and SMM e 0 the 8259A will revert to normal mask mode When ESMM e 0 SMM has no effect
Fully Nested Mode
This mode is entered after initialization unless another mode is programmed The interrupt requests are ordered in priority from 0 through 7 (0 highest) When an interrupt is acknowledged the highest priority request is determined and its vector placed on the bus Additionally a bit of the Interrupt Service register (ISO-7) is set This bit remains set until the microprocessor issues an End of Interrupt (EOI) command immediately before returning from the service routine or if AEOI (Automatic End of Interrupt) bit is set until the trailing edge of the last INTA While the IS bit is set all further interrupts of the same or lower priority are inhibited while higher levels will generate an interrupt (which will be acknowledged only if the microprocessor internal Interupt enable flip-flop has been re-enabled through software) After the initialization sequence IR0 has the highest prioirity and IR7 the lowest Priorities can be changed as will be explained in the rotating priority mode
Automatic End of Interrupt (AEOI) Mode
If AEOI e 1 in ICW4 then the 8259A will operate in AEOI mode continuously until reprogrammed by ICW4 in this mode the 8259A will automatically perform a non-specific EOI operation at the trailing edge of the last interrupt acknowledge pulse (third pulse in MCS-80 85 second in 8086) Note that from a system standpoint this mode should be used only when a nested multilevel interrupt structure is not required within a single 8259A The AEOI mode can only be used in a master 8259A and not a slave 8259As with a copyright date of 1985 or later will operate in the AEOI mode as a master or a slave
Automatic Rotation (Equal Priority Devices)
In some applications there are a number of interrupting devices of equal priority In this mode a device after being serviced receives the lowest priority so a device requesting an interrupt will have to wait in the worst case until each of 7 other devices are serviced at most once For example if the priority and ``in service'' status is Before Rotate (IR4 the highest prioirity requiring service)
End of Interrupt (EOI)
The In Service (IS) bit can be reset either automatically following the trailing edge of the last in sequence INTA pulse (when AEOI bit in ICW1 is set) or by a command word that must be issued to the 8259A before returning from a service routine (EOI command) An EOI command must be issued twice if in the Cascade mode once for the master and once for the corresponding slave There are two forms of EOI command Specific and Non-Specific When the 8259A is operated in modes which perserve the fully nested structure it can determine which IS bit to reset on EOI When a NonSpecific EOI command is issued the 8259A will automatically reset the highest IS bit of those that are set since in the fully nested mode the highest IS level was necessarily the last level acknowledged and serviced A non-specific EOI can be issued with OCW2 (EOI e 1 SL e 0 R e 0)
``IS'' Status
231468 - 18
Priority Status
231468 - 19
15
8259A
After Rotate (IR4 was serviced all other priorities rotated correspondingly) ture during its execution under software control For example the routine may wish to inhibit lower priority requests for a portion of its execution but enable some of them for another portion The difficulty here is that if an Interrupt Request is acknowledged and an End of Interrupt command did not reset its IS bit (i e while executing a service routine) the 8259A would have inhibited all lower priority requests with no easy way for the routine to enable them That is where the Special Mask Mode comes in In the special Mask Mode when a mask bit is set in OCW1 it inhibits further interrupts at that level and enables interrupts from all other levels (lower as well as higher) that are not masked Thus any interrupts may be selectively enabled by loading the mask register The special Mask Mode is set by OWC3 where SSMM e 1 SMM e 1 and cleared where SSMM e 1 SMM e 0
``IS'' Status
231468 - 20
Priority Status
231468 - 21
There are two ways to accomplish Automatic Rotation using OCW2 the Rotation on Non-Specific EOI Command (R e 1 SL e 0 EOI e 1) and the Rotate in Automatic EOI Mode which is set by (R e 1 SL e 0 EOI e 0) and cleared by (R e 0 SL e 0 EOI e 0)
Specific Rotation (Specific Priority)
The programmer can change priorities by programming the bottom priority and thus fixing all other priorities i e if IR5 is programmed as the bottom priority device then IR6 will have the highest one The Set Priority command is issued in OCW2 where R e 1 SL e 1 L0-L2 is the binary priority level code of the bottom priority device Observe that in this mode internal status is updated by software control during OCW2 However it is independent of the End of Interrupt (EOI) command (also executed by OCW2) Priority changes can be executed during an EOI command by using the Rotate on Specific EOI command in OCW2 (R e 1 SL e 1 EOI e 1 and LO-L2 e IR level to receive bottom priority)
Poll Command
In Poll mode the INT output functions as it normally does The microprocessor should ignore this output This can be accomplished either by not connecting the INT output or by masking interrupts within the microprocessor thereby disabling its interrupt input Service to devices is achieved by software using a Poll command The Poll command is issued by setting P e `1'' in OCW3 The 8259A treats the next RD pulse to the 8259A (i e RD e 0 CS e 0) as an interrupt acknowledge sets the appropriate IS bit if there is a request and reads the priority level Interrupt is frozen from WR to RD The word enabled onto the data bus during RD is D7 D6 D5 D4 D3 D2 D1 D0 I W2 W1 W0
Interrupt Masks
Each Interrupt Request input can bem masked individually by the Interrupt Mask Register (IMR) programmed through OCW1 Each bit in the IMR masks one interrupt channel if it is set (1) Bit 0 masks IR0 Bit 1 masks IR1 and so forth Masking an IR channel does not affect the other channels operation
W0 - W2 Binary code of the highest priority level requesting service I Equal to ``1'' if there is an interrupt This mode is useful if there is a routine command common to several levels so that the INTA sequence is not needed (saves ROM space) Another application is to use the poll mode to expand the number of priority levels to more than 64
Special Mask Mode
Some applications may require an interrupt service routine to dynamically alter the system priority struc-
Reading the 8259A Status
The input status of several internal registers can be read to update the user information on the system
16
8259A
NOTES 231468 - 22 1 Master clear active only during ICW1 2 FREEZE is active during INTA and poll sequences only 3 Truth Table for a D-Latch CD Q Operation 1 0 Di X Di Qn-1 Follow Hold
Figure 9 Priority Cell The following registers can be read via OCW3 (IRR and ISR or OCW1 IMR )
Simplified Logic Diagram There is no need to write an OCW3 before every status read operation as long as the status read corresponds with the previous one i e the 8259A ``remembers'' whether the IRR or ISR has been previously selected by the OCW3 This is not true when poll is used After initialization the 8259A is set to IRR For reading the IMR no OCW3 is needed The output data bus will contain the IMR whenever RD is active and A0 e 1 (OCW1) Polling overrides status read when P e 1 RR e 1 in OCW3
Interrupt Request Register (IRR) 8-bit register which contains the levels requesting an interrupt to be acknowledged The highest request level is reset from the IRR when an interrupt is acknowledged (Not affected by IMR ) In-Service Register (ISR) 8-bit register which contains the priority levels that are being serviced The ISR is updated when an End of Interrupt Command is issued Interrupt Mask Register 8-bit register which contains the interrupt request lines which are masked
The IRR can be read when prior to the RD pulse a Read Register Command is issued with OCW3 (RR e 1 RIS e 0 ) The ISR can be read when prior to the RD pulse a Read Register Command is issued with OCW3 (RR e 1 RIS e 1)
Edge and Level Triggered Modes
This mode is programmed using bit 3 in ICW1 If LTIM e `0' an interrupt request will be recognized by a low to high transition on an IR input The IR input can remain high without generating another interrupt
17
8259A
231468 - 23
Figure 10 IR Triggering Timing Requirements If LTIM e `1' an interrupt request will be recognized by a `high' level on IR Input and there is no need for an edge detection The interrupt request must be removed before the EOI command is issued or the CPU interrupts is enabled to prevent a second interrupt from occurring The priority cell diagram shows a conceptual circuit of the level sensitive and edge sensitive input circuitry of the 8259A Be sure to note that the request latch is a transparent D type latch In both the edge and level triggered modes the IR inputs must remain high until after the falling edge of the first INTA If the IR input goes low before this time a DEFAULT IR7 will occur when the CPU acknowledges the interrupt This can be a useful safeguard for detecting interrupts caused by spurious noise glitches on the IR inputs To implement this feature the IR7 routine is used for ``clean up'' simply executing a return instruction thus ignoring the interrupt If IR7 is needed for other purposes a default IR7 can still be detected by reading the ISR A normal IR7 interrupt will set the corresponding ISR bit a default IR7 won't If a default IR7 routine occurs during a normal IR7 routine however the ISR will remain set In this case it is necessary to keep track of whether or not the IR7 routine was previously entered If another IR7 occurs it is a default ing ICW4) This mode is similar to the normal nested mode with the following exceptions a When an interrupt request from a certain slave is in service this slave is not locked out from the master's priority logic and further interrupt requests from higher priority IR's within the slave will be recognized by the master and will initiate interrupts to the processor (In the normal nested mode a slave is masked out when its request is in service and no higher requests from the same slave can be serviced ) b When exiting the Interrupt Service routine the software has to check whether the interrupt serviced was the only one from that slave This is done by sending a non-specific End of Interrupt (EOI) command to the slave and then reading its In-Service register and checking for zero If it is empty a non-specific EOI can be sent to the master too If not no EOI should be sent
Buffered Mode
When the 8259A is used in a large system where bus driving buffers are required on the data bus and the cascading mode is used there exists the problem of enabling buffers The buffered mode will structure the 8259A to send an enable signal on SP EN to enable the buffers In this mode whenever the 8259A's data bus outputs are enabled the SP EN output becomes active This modification forces the use of software programming to determine whether the 8259A is a master or a slave Bit 3 in ICW4 programs the buffered mode and bit 2 in ICW4 determines whether it is a master or a slave
The Special Fully Nest Mode
This mode will be used in the case of a big system where cascading is used and the priority has to be conserved within each slave In this case the fully nested mode will be programmed to the master (us-
18
8259A
The cascade bus lines are normally low and will contain the slave address code from the trailing edge of the first INTA pulse to the trailing edge of the third pulse Each 8259A in the system must follow a separate initialization sequence and can be programmed to work in a different mode An EOI command must be issued twice once for the master and once for the corresponding slave An address decoder is required to activate the Chip Select (CS) input of each 8259A The cascade lines of the Master 8259A are activated only for slave inputs non-slave inputs leave the cascade line inactive (low)
CASCADE MODE
The 8259A can be easily interconnected in a system of one master with up to eight slaves to handle up to 64 priority levels The master controls the slaves through the 3 line cascade bus The cascade bus acts like chip selects to the slaves during the INTA sequence In a cascade configuration the slave interrupt outputs are connected to the master interrupt request inputs When a slave request line is activated and afterwards acknowledged the master will enable the corresponding slave to release the device routine address during bytes 2 and 3 of INTA (Byte 2 only for 8086 8088)
231468 - 24
Figure 11 Cascading the 8259A
19
8259A
ABSOLUTE MAXIMUM RATINGS
Ambient Temperature Under Bias Storage Temperature Voltage on Any Pin with Respect to Ground Power Dissipation 0 C to 70 C
b 65 C to a 150 C b 0 5V to a 7V
NOTICE This is a production data sheet The specifications are subject to change without notice
1W
WARNING Stressing the device beyond the ``Absolute Maximum Ratings'' may cause permanent damage These are stress ratings only Operation beyond the ``Operating Conditions'' is not recommended and extended exposure beyond the ``Operating Conditions'' may affect device reliability
D C CHARACTERISTICS
Symbol VIL VIH VOL VOH VOH(INT) ILI ILOL ICC ILIR Parameter
TA e 0 C to 70 C VCC e 5V g 10% Min
b0 5
Max 08 VCC a 0 5V 0 45
Units V V V V V V
Test Conditions
Input Low Voltage Input High Voltage Output Low Voltage Output High Voltage Interrupt Output High Voltage Input Load Current Output Leakage Current VCC Supply Current IR Input Load Current
20
IOL e 2 2 mA IOH e b 400 mA IOH e b 100 mA IOH e b 400 mA 0V s VIN s VCC 0 45V s VOUT s VCC VIN e 0 VIN e VCC
24 35 24
b 10 b 10 a 10 a 10
mA mA mA mA mA
85
b 300
10
NOTE For Extended Temperature EXPRESS VIH e 2 3V
CAPACITANCE
Symbol CIN CI O
TA e 25 C VCC e GND e 0V Min Typ Max 10 20 Unit pF pF Test Conditions fc e 1 MHz Unmeasured Pins Returned to VSS
Parameter Input Capacitance I O Capacitance
20
8259A
A C CHARACTERISTICS
TIMING REQUIREMENTS Symbol TAHRL TRHAX TRLRH TAHWL TWHAX TWLWH TDVWH TWHDX TJLJH TCVIAL TRHRL
TA e 0 C to 70 C VCC e 5V g10%
Parameter AO CS Setup to RD INTAv AO CS Hold after RD INTAu RD Pulse Width AO CS Setup to WRv AO CS Hold after WRu WR Pulse Width Data Setup to WRu Data Hold after WRu Interrupt Request Width (Low) Cascade Setup to Second or Third INTAv (Slave Only) End of RD to Next RD End of INTA to Next INTA within an INTA Sequence Only End of WR to Next WR End of Command to Next Command (Not Same Command Type) End of INTA Sequence to Next INTA Sequence
8259A Min 0 0 235 0 0 290 240 0 100 55 Max
8259A-2 Min 0 0 160 0 0 190 160 0 100 40 Max
Units ns ns ns ns ns ns ns ns ns ns
Test Conditions
See Note 1
160 190 500 500
100 100 150 300
ns ns ns
TWHWL TCHCL
Worst case timing for TCHCL in an actual microprocessor system is typically much greater than 500 ns (i e 8085A e 1 6 ms 8085A-2 e 1 ms 8086 e 1 ms 8086-2 e 625 ns) NOTE This is the low time required to clear the input latch in the edge triggered mode
TIMING RESPONSES Symbol TRLDV TRHDZ TJHIH TIALCV TRLEL TRHEH TAHDV TCVDV Parameter Data Valid from RD INTAv Data Float after RD INTAu Interrupt Output Delay Cascade Valid from First INTAv (Master Only) Enable Active from RDv or INTAv Enable Inactive from RDu or INTAu Data Valid from Stable Address Cascade Valid to Valid Data 10 8259A Min Max 200 100 350 565 125 150 200 300 10 8259A-2 Min Max 120 85 300 360 100 150 200 200 ns ns ns ns ns ns ns ns C of Data Bus e 100 pF C of Data Bus Max Test C e 100 pF Min Test C e 15 pF CINT e 100 pF CCASCADE e 100 pF Units Test Conditions
21
8259A
A C TESTING INPUT OUTPUT WAVEFORM
A C TESTING LOAD CIRCUIT
231468 - 25 A C Testing Inputs are driven at 2 4V for a logic ``1'' and 0 45V for a logic ``0'' Timing measurements are made at 2 0V for a logic ``1'' and 0 8V for a logic ``0'' 231468 - 26 CL e 100 pF CL Includes Jig Capacitance
WAVEFORMS
WRITE
231468 - 27
22
8259A
WAVEFORMS (Continued)
READ INTA
231468 - 28
OTHER TIMING
231468 - 29
23
8259A
WAVEFORMS
INTA SEQUENCE
(Continued)
231468 - 30
NOTES Interrupt output must remain HIGH at least until leading edge of first INTA 1 Cycle 1 in 8086 8088 systems the Data Bus is not active
Data Sheet Revision Review
The following changes have been made since revision 2 of the 8259A data sheet 1 The first paragraph of the Poll Command section was rewritten to clarify the status of the INT pin 2 A paragraph was added to the Interrupt Sequence section to indicate the status of the INT pin during multiple interrupts 3 A reference to PLCC packaging was added 4 All references to the 8259A-8 have been deleted
INTEL CORPORATION 2200 Mission College Blvd Santa Clara CA 95052 Tel (408) 765-8080 INTEL CORPORATION (U K ) Ltd Swindon United Kingdom Tel (0793) 696 000 INTEL JAPAN k k Ibaraki-ken Tel 029747-8511
Printed in U S A xxxx 1196 B10M xx xx


▲Up To Search▲   

 
Price & Availability of ID8259A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X